Critical Force Measurement with ZT-1 & ZT-4
The ZT tonnage load module is designed for critical force measurement applications where accuracy, extreme stability, and dependable noise rejection is essential. It is equipped with an LED bar-graph voltmeter for easy setup and diagnostic. The ZT is DIN rail mountable and is designed to interface with a PLC analog card and to display output through a human machine interface (HMI).
The ZT module is available in Single-Channel (the ZT-1 as pictured above) and in Four-Channels (the ZT-4 as pictured to the right).
ZT-1 | ZT-4 | |
Designed to work with strain gauge sensors and load cells. The ZT can also accept input from 4-20mA current output sensors or voltage output sensors. |
✓ | ✓ |
Simultaneously provides normal peak, reverse peak, and track voltage outputs. |
✓ | ✓ |
Simultaneously provides normal peak, reverse peak, and track 0-20mA current outputs. |
✓ | |
Built-in threshold trigger simplifies installation. External probe trigger can also be used when situation required. |
✓ | ✓ |
LED bar-graph voltmeter for easy setup and diagnostic. |
✓ | ✓ |
Built-in 1 Mega Ohm calibration shunt resistor. |
✓ | ✓ |
User selected external shunt resistor can be used for load cell applications. |
✓ | |
x1 and x10 amplifier gain ranges to work with either strong or weak signal from the load sensor. |
✓ | ✓ |
Auto-Zero can be selected using dip switches to compensate for zeroing errors caused by environmental changes such as temperature, humidity, and etc. |
✓ | ✓ |
Electrical noise rejection filter can be enabled when situation required. |
✓ | ✓ |
Plug-in connectors for easy wiring and installation. |
✓ | ✓ |
Standard DIN Rail mount simplifies systems integration. |
✓ | ✓ |
Modular with common bus design allows future upgrade and expansion. |
✓ | ✓ |
CE Certified | ✓ | ✓ |
Transducers | Full bridge, 120 to 1000 ohms. |
Sensor Excitation | Built in +10VDC at 250mA max. |
Balance Range | +/- 1mV/V of sensor imbalance |
Gain Ranges | Low range = x50 to x550 adjustable High range = x500 to x5,500 adjustable |
Calibration Shunt | Built-in 1 mega ohm (.1%), or external custom shunt (ZT-1 only) |
Output Range - Voltage |
Normal Peak and Reverse Peak = 0 to 10VDC Track output = -10 to +10VDC |
Output Range - Current (ZT-1 only) |
Normal Peak and Reverse Peak = 0 to 20mA Track output = -20 to +20mA |
Circuit Inaccuracy | +/- .1% of full scale max. |
Circuit Non-linearity |
+/- .02% of full scale max. |
Auto Zero | Time constant = 10 seconds. DIP switch selectable. |
Frequency Response |
DC to 5,000 Hz |
Speed Limit | 2000 SPM max. when triggered by External Probe 500 SPM max. when triggered by Internal Threshold |
Operating Temperature |
-4 to 158 degree F, or -20 to 70 degree C |
Display | LED bar-graph voltmeter for setup and diagnostic |
Trigger | Internal Threshold (.35V / .70V), or External Probe. |
Probe Input | NPN/PNP proximity probes, solid state or dry contact relays. Built-in 24VDC at 80mA max. supplies power to the probe. |
Input Power | 24VDC at 300mA max. Automatic resettable fuse. |
Mounting | Standard DIN Rail mount |
Width | Height | Depth | |
Dimensions (ZT-1) | 0.9 " | 4.1 " | 4.7 " |