The TR-2 Resolver provides precise crank-angle position measurements.

Resolvers are incorporated with different types of press monitoring and automation systems. These systems will help your production run smooth by providing the accuracy and reliability that you are looking for. Our resolvers are compatible with AMCI resolver modules used in PLC applications.

  Standard
3/4" stainless steel shaft
Corrosion resistant shaft
Sealed ball bearings to maximize life
Rugged resolver enclosure, sealed
  w/gasket
mounting foot for easy installation
   
Input Voltage 7.0 Vrms
Input Frequency 5000 Hz
Primary Winding Rotor (R1,R2)
Input Rotor
  Current (max)
10.9 mA
Input Power 47 mW
Output Voltage
  (stator windings)
6.7 Vrms
Transfer Ratio .95
Phase Shift (open
  circuit) Leading
-6 Degrees
Sensitivity 116 mV/deg.
DC Rotor
  Resistance
16 ohms +/- 10% ohms
DC Stator
  Resistance
52 ohms +/- 10% ohms
Total Null Voltage 15 mV
Accuracy Maximum
  Error
+/-7 Minutes
Type Name Description Link
Standard Product Shielded Cable 15' shield resolver cable Inquire
Standard Product Shielded Cable 30' shield resolver cable Inquire
Standard Product Shielded Cable 50' shield resolver cable Inquire
Standard Product Shielded Cable 100' shield resolver cable Inquire

Want to Learn More?